Salient Pole Generator
Product Code : LSK-EPS-10521
The Salient Pole Generator is a power systems trainer for exploring how salient pole generators behave. A prime mover and generator sit on a common bed-plate in the console, with characteristics similar to industrial turbine and generator sets. Resistive, capacitive and inductive load banks, synchronising aids and a protection relay are built in.
Specifications of the Salient Pole Generator
| Specification | Value |
|---|---|
| Machines | Prime mover and generator set: two coupled machines on a common bed-plate in the base of the console |
| Speed control | Vector drive for the prime mover, allowing load flow in positive and negative directions |
| Excitation | Manual or automatic voltage regulation |
| Overrun | Resistors dissipate the reverse power |
| Load angle | Integral shaft encoder |
| Loads | Resistive, capacitive and inductive load banks |
| Synchronising | Synchroscope or a set of three coloured lamps; variable quadrature droop for reactive power once synchronised |
| Protection | Relay connected through current transformers and a voltage transformer; set locally or from a computer (computer not included, software included); socket for an extra relay |
| Waveforms | Transducers with BNC connections for an external oscilloscope (not supplied) |
| Leads and safety | Set of shrouded leads; emergency switch, mains supply isolator and protection fuses |
| Supplied by | Science Lab Supplies, Ambala, India |
Generator Tests on the Salient Pole Set
The vector drive sets the prime mover speed, and the excitation sets the generator voltage by hand or by automatic regulation. Students load the generator on its own load banks, or synchronise it to the mains, and link the test circuits with the shrouded leads.
- Load characteristics: record voltage and current for resistive, capacitive and inductive loads at fixed speed and excitation.
- Synchronising: bring the generator to speed and voltage, then close onto the mains using the synchroscope or the three lamps.
- Load angle and load flow: once synchronised, drive power in either direction and read the load angle from the shaft encoder. In overrun, resistors absorb the reverse power.
- Protection: set the relay for line and earth current, voltage and frequency faults, apply faults and watch the breakers open.
- Waveforms: view voltage and current through the BNC transducers on an Oscilloscope or a PC Oscilloscope.
Safety: never close the breaker onto the mains until the synchronising aids agree, and isolate the supply before rewiring.
Frequently Asked Questions
Which items outside the set does a lab need?
An external oscilloscope for the BNC waveform outputs, and a computer if the relay will be set by cable. A further relay for the spare socket is optional. The load banks are already part of the set.
Which tests can a college run on this generator?
Load characteristics on the three load banks, voltage control by hand or automatic regulation, and synchronising to the mains. Synchronised running adds load angle, two-way load flow and reactive power control, and relay tests work in both states.
How is the generator synchronised with the three lamps?
The lamps are connected across the open breaker. While the generator and mains differ in voltage, frequency or phase, the lamps flicker. When they go dark together and stay dark, the two sides match and the breaker can be closed.
How does a salient pole rotor differ from a round rotor?
Its poles project from the rotor, so the air gap is uneven. That suits slow machines with many poles, such as hydro generators. Because the gap differs along the pole and between poles, the machine has two reactances, direct axis and quadrature axis.
What does the load angle tell students?
It is the angle between the rotor position and the voltage it is locked to. It grows as the generator delivers more real power. Past its stable limit the machine slips out of step, so the encoder reading shows how close it is.
What is hunting in a synchronous generator?
After a sudden change in load or drive, the rotor can swing back and forth about its steady load angle. These oscillations are called hunting. Damping in the machine and steady control settings make them die away.
Related Generation and Protection Equipment
- Second Generator for Electrical Power System Simulator: vector drive and manual or automatic excitation on a second motor-generator set.
- Electrical Power System Simulator: grid transformer and phase-angle meter for synchronising its generator to the grid bus.
- Differential Protection Relay: numerical relay with magnetising inrush restraint for two-winding apparatus.
- Power Factor Load Bank: three independent lines for star or delta, balanced or unbalanced loads.
- Three Phase Mobile Transformer: three-limb transformer with accessible high and low voltage tappings.
Generators, transformers, lines and relays for power engineering are listed together under Electrical Power System in the Engineering Laboratory Equipment section.
Shipping this generator trainer to Uganda, the UAE, Saudi Arabia, Oman, the Philippines or Nepal is possible because Science Lab Supplies holds an Importer-Exporter Code. Start a quotation from the contact page, or note the trainer in the enquiry cart while planning the lab.