Power Factor Load Bank
Product Code : LSK-EPS-10534
The Power Factor Load Bank is a free-standing, mobile load with separate resistive, inductive and capacitive banks. Used alone or combined, the banks give unity, lagging (inductive) or capacitive power factor on single-phase or three-phase circuits, and each of its three lines can be set to its own value for balanced or unbalanced load tests.
Specifications of the Power Factor Load Bank
| Specification | Value |
|---|---|
| Load banks | Three separate banks: resistive, inductive and capacitive, used alone or in combination |
| Power factor | Unity (resistive only), lagging (inductive) or capacitive |
| Inputs | Three independent lines: Lines 1, 2 and 3 |
| Circuits | Single-phase or three-phase; the lines connect as a star or delta load |
| Load balance | Each line set to its own value for balanced or unbalanced load tests |
| Voltage selection | Voltage-selector switch for different line voltages |
| Construction | Free-standing unit on small wheels, with a worktop for instruments or recording results |
| Supplied by | Science Lab Supplies, Ambala, India |
Power Factor and Load Tests in the Machines Lab
Lines 1, 2 and 3 are wired to the source under test through the meters: all three as a star or delta load for three-phase work, or one line for a single-phase circuit. The voltage selector is set first, then the banks are switched in step by step. Meters and the results sheet sit on the worktop.
- Load types: run the resistive bank alone for unity power factor, then add inductive steps for a lagging load and capacitive steps so the current leads the voltage; record voltage, current and power and draw the power triangle.
- Compensation: hold an inductive load and switch in capacitive steps until the line current is lowest, the idea behind a static VAr compensator in industrial plants.
- Transformer loading: load the secondary of the Three Phase Mobile Transformer at unity, lagging and capacitive power factor and compare the change in secondary voltage.
- Generator loading: connect the bank to the Salient Pole Generator and note how the excitation must change to hold the terminal voltage as the power factor moves.
- Unbalanced star load: set a different value on each line and measure the neutral current.
Change connections only with the supply isolated, and allow a short wait after switch-off, as capacitive loads can hold a charge.
Frequently Asked Questions
Can the load bank be used on different mains voltages?
Yes. A voltage-selector switch lets it work with different line voltages on single-phase and three-phase circuits. Read the line voltage of the source under test and set the selector to match before any bank is switched in.
Which practicals can a distributor list for this load bank?
Unity, lagging and capacitive power factor; real, reactive and apparent power; balanced and unbalanced three-phase loads in star or delta; transformer and generator loading at a chosen power factor; and the principle of a static VAr compensator.
Why does switching in capacitance raise the power factor of an inductive load?
An inductive load draws reactive current that lags the voltage, while a capacitor draws reactive current that leads it. Together the two partly cancel, so the supply carries less reactive current for the same real power and the power factor moves towards unity.
How can students tell whether the current leads or lags the voltage?
Compare current and voltage on an oscilloscope, or read a power factor meter. With inductive banks the current peak comes after the voltage peak, so it lags; with capacitive banks it comes before. Agree the sign used for reactive power before plotting results.
Why is a low power factor a problem in real supply systems?
For the same real power, a low power factor needs more current. The extra current raises losses and voltage drop in cables, transformers and generators, so factories and utilities add capacitors or static VAr compensators to keep the power factor near unity.
Related Load Banks for Machines and Power Labs
- Portable Resistive Load Bank: steel enclosure with three banks of switchable resistors, each bank protected by a thermal circuit-breaker.
- Laboratory Capacitive Loading Unit 1.2 kVAR: balanced three-phase array of metallised polypropylene film capacitors.
- Electrical Inductor Load Bank 2.4 kVAR: balanced three-phase copper coils on laminated cores for lagging loads.
- Inductive Load 415V AC Three Phase: equal inductive steps across all three lines.
- Electrical Lamp Load Bank 2.5 kW: switchable incandescent lamps up to 2500 W, with a fuse for each lamp channel.
The load bank sits in the Electrical Power System range with the generator, line and relay trainers; the wider Engineering Laboratory Equipment section covers other engineering labs.
Under its Importer-Exporter Code, Science Lab Supplies can arrange shipment of this load bank to Malaysia, Peru, Egypt, Iraq, Nigeria and Kenya. Ask for a quotation on the contact page, or list the unit in the enquiry cart together with other lab items.