Germinating Seed Respiration Demonstration Kit
Product Code : SCL-BLE-11619
The Germinating Seed Respiration Demonstration Kit shows that seeds take in oxygen as they respire. Seeds go in one of two matched 30 mL vessels and inert control beads in the other. A carbon dioxide absorbent, ordered separately, takes up the gas the seeds give out, so a drop of coloured indicator moves along a 1 mL capillary graduated in 0.01 mL.
Specifications of the Seed Respiration Kit
| Specification | Value |
|---|---|
| Vessels | 2, matched, 30 mL each: one for seeds, one for the control |
| Connectors | 2, sealed |
| Capillary | Graduated, 1 mL in 0.01 mL divisions, nominal bore about 2 mm |
| Support | Stand for the vessels and capillary |
| Control | Inert control beads |
| Indicator | Water-based coloured indicator, 2 bottles |
| Carbon dioxide absorbent | Not in the kit (equipment only); ordered separately, with its own label and SDS |
| Supplied by | Science Lab Supplies, Ambala, India |
Measuring Seed Respiration in the Capillary Tubes
Soaked seeds are germinated for two or three days, then placed in one vessel, kept apart from the absorbent by a plug of cotton wool. The matched control vessel takes the same volume of inert beads and the same amount of absorbent. A drop of coloured indicator is drawn into the graduated capillary and its start is read. Both vessels stand in one water bath so the temperature stays steady, and both sealed connectors must be gas-tight.
- Oxygen uptake (Class 11): read the drop on the 0.01 mL scale every few minutes and plot the volume taken up against time.
- Effect of temperature: stand both vessels in water at different temperatures, checked with Laboratory Thermometers, and compare the rates.
- Germinating against dry seeds: sprout seeds on damp paper in a Glass Petri Dish with Cover, 100 mm and compare them with dry seeds of the same kind.
Precautions: the kit holds no absorbent. Where potassium hydroxide is ordered as the carbon dioxide absorbent, treat it as a corrosive chemical: wear eye protection and chemical-resistant gloves, and keep the seeds from touching it. Wash any splash off skin or eyes with plenty of running water. Clean up spills at once and dispose of used alkali as chemical waste, following the label and safety data sheet of the absorbent supplied. Let the vessels settle at the bath temperature before the first reading.
Frequently Asked Questions
How often must the potassium hydroxide and dye be replaced?
The kit carries no potassium hydroxide: the absorbent is ordered separately, with its own label and SDS, and renewed once it stops taking up carbon dioxide. The coloured indicator in the two bottles is used a drop at a time. Seeds are bought locally and soaked a few days before each class.
How does this kit differ from a manometer respirometer?
In this kit a drop of coloured indicator moves along one graduated 1 mL capillary, read in 0.01 mL steps, between two matched 30 mL vessels on sealed connectors. A manometer respirometer instead joins two stoppered tubes to a U-shaped graduated manometer with taps.
How should staff handle the potassium hydroxide?
Potassium hydroxide, ordered separately as the carbon dioxide absorbent, is corrosive to skin and eyes. Handle it in goggles and chemical-resistant gloves, follow its own label and SDS, keep it away from seeds and animals, and wash any splash off with plenty of running water. Keep the bottle closed, as the alkali takes up carbon dioxide from air.
Why does the dye drop move towards the seeds?
The seeds use oxygen and give out carbon dioxide, which the potassium hydroxide absorbs. The gas volume in the seed vessel falls, and the lower pressure pulls the drop towards it.
What should the control tube contain?
The inert control beads of the kit, in the same volume as the seeds, with the same amount of absorbent. Since both 30 mL vessels are matched, changes in room temperature or pressure act on both alike and are not counted as respiration.
How is the rate worked out from the drop?
Divide the volume taken up by the time taken. The capillary is graduated over 1 mL in 0.01 mL divisions, so the volume is read straight from its scale. On an ungraduated tube it would be distance times the bore area, pi times r squared.
Related Seed and Respiration Kits
- Support Stand and Beaker Set for Plant Experiments: tripod stand with a 500 mm rod, an 85 mm ring with clamp and a 600 ml beaker.
- Kit for Demonstration of CO2 Emission and Heat Production in Germinating Seeds: 100 mL ready-to-use limewater, two 250 mL flasks, a low-flow hand bulb and two thermometers in matched insulated vessels.
- Simple Respirometer: two tubes closed with corks, fitted with three-way taps and joined to a graduated manometer.
- Respirometer: two stoppered boiling tubes on three-way taps; one holds the organisms and a syringe, the other is a control thermobarometer.
- Kit for Experiments on Photosynthesis: CO2 sensor set for following plant respiration and seed germination.
Browse Biology Lab Equipment for more plant physiology sets, or the wider School Lab Equipments section.
Export orders from Ethiopia, Tanzania, Uganda, the UAE, Saudi Arabia and Oman can be handled, as Science Lab Supplies holds an Importer-Exporter Code. For a quotation, describe the order on the contact page or add the seed kit to the enquiry cart.
Last updated: 19 November 2026