Graduated Pipettes, 2 ml, 5 ml and 10 ml
Product Code : SCL-CL-11696
These Graduated Pipettes are glass measuring pipettes in 2 ml, 5 ml and 10 ml capacities, each 350 mm long. The scale along the tube lets one pipette deliver any volume up to its capacity, for dilutions and for adding measured amounts of reagent.
Specifications of the Graduated Pipettes
| Specification | Value |
|---|---|
| Type | Graduated measuring pipette |
| Capacities | 2 ml, 5 ml and 10 ml |
| Length | 350 mm |
| Material | Glass, chemical resistant and heat resistant |
| Supplied by | Science Lab Supplies, Ambala, India |
Measuring Volumes with Graduated Pipettes
Draw the liquid up with a Pipette Filler Bulb, set it to a starting mark, and let it run out to the second mark. Between uses, keep the pipettes upright in a Pipette Holder so they drain and stay clean.
- Dilution series: take 1, 2, 3 and 4 ml of a stock solution with the 5 ml pipette and make each up to 10 ml with water.
- Measured reagent additions: add an indicator or reactant in steps of 0.5 ml or less and note the change.
- Rate of reaction: deliver the same small volume of acid to each tube so only the temperature or concentration changes.
Common errors: starting the reading from the wrong end of the scale, and letting air bubbles stay in the tip.
Frequently Asked Questions
What is the difference between Mohr and serological graduated pipettes?
In a Mohr type the graduations stop above the tip, so you deliver between two marks. In a serological type the scale runs down to the tip and the liquid in the tip is part of the volume.
Should I blow out the last drop?
Only if the pipette is a blow-out type, which is usually marked with a ring near the top. A to-deliver pipette is calibrated to drain freely and leave the small amount in the tip.
How do I read the scale correctly?
Hold the pipette vertical with the mark at eye level, wait until the liquid is still, and read the bottom of the meniscus. Reading from above or below gives a parallax error.
Is a graduated pipette as accurate as a bulb pipette?
For one fixed volume a bulb (volumetric) pipette is usually more accurate. A graduated pipette is chosen when you need several different volumes from the same tool.
Why use a filler bulb and not the mouth?
Mouth pipetting can draw reagent into the mouth. A rubber filler gives steady suction and lets the liquid down slowly to the mark.
Related Pipettes and Volumetric Glassware
- Graduated Pipettes 2ml: single graduated glass pipette of 2 ml capacity.
- Graduated Pipette, 10 ml: graduated glass pipette of 10 ml capacity.
- Graduated Pipettes 25ml: graduated glass pipette of 25 ml capacity.
- Volumetric (One-Mark) Pipette, 5 ml: sealed glass pipette of 5 ml capacity.
- Glass Pipettes, 2 ml, 5 ml and 20 ml: clear glass pipettes of 2 ml and 5 ml at 450 mm and 20 ml at 530 mm.