Electrode Rod Platinum
Product Code : LSK-CL-10058
The Electrode Rod Platinum is a 100 x 10 mm rod in a glass tube with a terminal, ending in a leaf of platinum. Platinum is an inert electrode material, so it takes no part in the reaction and gives clean gas volumes in electrolysis and voltameter work.
Specifications of the Platinum Electrode Rod
| Specification | Value |
|---|---|
| Rod | 100 x 10 mm, in a glass tube |
| Electrode tip | Leaf of platinum at the end of the rod |
| Connection | Terminal |
| Use | Electrochemistry experiments |
| Supplied by | Science Lab Supplies, Ambala, India |
Using Platinum Electrodes in Electrolysis
Only the platinum leaf touches the electrolyte; the glass tube covers the rest of the rod and keeps it out of the solution. Two electrodes are wired to a DC supply such as a Laboratory Battery Eliminator.
- Electrolysis of acidified water: fit platinum electrodes to a Hoffman Voltameter With Electrodes and show that hydrogen and oxygen form in a 2 to 1 volume ratio.
- Carbon or platinum: run the same electrolysis with carbon electrodes and compare the oxygen volume collected at the anode.
- Electrolysis of salt solutions: use platinum electrodes where the products must come only from the electrolyte, for example in copper sulphate solution.
Care: never bend the leaf, rinse in deionised water after use, and store the electrodes so that the tips touch nothing.
Frequently Asked Questions
What is the platinum electrode's job in a hydrogen or iron(II)/iron(III) half-cell?
These half-cells have no solid metal of their own to join to the circuit. The platinum dips into the solution and passes electrons between the ions, or hydrogen gas and hydrogen ions, and the wire without reacting itself. In the hydrogen half-cell the gas is bubbled over the platinum.
How far should the platinum leaf be dipped into the solution?
Far enough to cover the whole leaf, with the glass tube, not the terminal, passing through the liquid surface. A fully covered leaf gives a steady current, and a dry terminal does not corrode or add products of its own.
Which apparatus is this platinum electrode usually ordered for?
Mainly water voltameters and other electrolysis cells where the products must come only from the electrolyte. The glass-covered rod passes through a rubber stopper or the electrode opening of the apparatus, so check that the 100 x 10 mm rod suits that opening before ordering.
What should be checked when a platinum electrode is unpacked?
Look at the leaf for bends, tears or dark deposits, check the glass tube for cracks, and make sure the terminal is firm. Deposits come off with a short dip in warm dilute acid and a rinse in deionised water. Never scrape the leaf, as it tears easily.
Can a bent platinum leaf be flattened again?
A slight bend can be eased flat with plastic tweezers on a clean, smooth surface, because platinum is soft. Sharp creases weaken the thin leaf and may split it, so store the electrode with its tip touching nothing and handle it by the glass tube.
Related Electrolysis Apparatus
- Platinum Foil Electrodes (Pair): pair of rectangular foil electrodes fused into glass tubes with screw terminals.
- Electrode Rod Carbon Voltameter: 100 x 10 mm carbon rod in a glass tube with terminal.
- Voltameter: base with terminals, platinum electrodes and two 10 ml graduated test tubes.
- Hofmann Voltameter Stand: metal stand with support clamp and 600 mm rod.
- Salt Bridge: 13 mm arms, for measuring cell EMF under forward, zero and reverse current.
More inert electrodes and electrolysis apparatus are grouped under the Chemistry Lab range in School Lab Equipments.
Science Lab Supplies exports platinum electrodes to Tanzania, Uganda, the UAE, Saudi Arabia, Oman and the Philippines on its Importer-Exporter Code. Platinum electrode quotations can be requested from the contact page or the enquiry cart.
Last updated: 15 November 2026