Hand Wheel Type Vertical Autoclave
Product Code : LSK-A-11379
Hand Wheel Type Vertical Autoclave (SKU LSK-A-11379) is a vertical steam sterilizer with a hand-wheel quick-open door, five fixed and four DIY programs, and a fully automatic cycle from water filling and dynamic pulse exhaust to sterilising, draining and drying. Its programs cover dressings, equipment, tools, rubber, liquids, culture medium and waste. Science Lab Supplies quotes and ships this autoclave from Ambala, India, to laboratories, institutions and tender contractors.
Specifications
Features and safety systems of the hand-wheel vertical autoclave are tabulated below. In short, it removes cold air by a 98–102 °C exhaust method plus dynamic pulse exhaust, keeps steam inside during sterilisation via an inner stainless steel water tank, and protects users with door, water-level, temperature, pressure and electrical safeguards.
| Specification | Value |
|---|---|
| SKU | LSK-A-11379 |
| Type | Vertical steam autoclave, hand-wheel door |
| Programs | 5 fixed and 4 DIY programs |
| Load types | Dressings, equipment, tools, rubber, liquid, culture medium, waste |
| Automatic process | Water filling, dynamic pulse exhaust, heating, sterilising, draining, drying |
| Air removal | Exhaust at 98–102 °C plus dynamic pulse exhaust |
| Exhaust selection | Automatic quick or slow exhaust to avoid liquid overflow |
| Door | Hand-wheel quick-open structure with self-expandable sealing ring |
| Door cover | Safety shell of thermal insulation material |
| Door sensor | Operation stops if the door is open |
| Water system | Inner stainless steel water tank; water inlet filter |
| Steam during sterilisation | Not exhausted, keeping the outside clean and dry |
| Display | LED screen: all process steps and error codes |
| Over-temperature protection | System powers off automatically |
| Over-pressure protection | Safety valve opens automatically |
| Anti-dry-out | Powers off with an error code if water level is too low |
| Electrical protection | Air switch for over-current, over-voltage and leakage |
| Service access | Independent quick service window |
| Printer | Optional, for recording sterilisation data |
| Capacity, chamber size and power supply | Confirmed on the quotation |
| Supplied by | Science Lab Supplies, Ambala, India |
Applications and Experiments for the Hand Wheel Type Vertical Autoclave
Once the load is in and the hand wheel closed, the operator selects a fixed or DIY program and the unit fills, exhausts, heats, sterilises, drains and dries automatically. Quick or slow exhaust is chosen automatically to stop liquids boiling over, which suits culture medium and liquid loads in a laboratory setting.
- Culture medium cycles before plates are poured into a 90 mm Petri Dish Glass With Lid.
- Preparing work for the Incubation Oven, which runs from ambient +1 to 60 °C for agar plates.
- Dressings, equipment, tools, rubber and waste on their own programs.
Hot steam and liquids can scald; never force the door, and let only trained staff run the unit.
Standard Scope of Supply
One Hand Wheel Type Vertical Autoclave is supplied with its programs, LED controller, inner water tank and the safety systems above. The optional printer, baskets or other accessories can be added to the quotation, which also confirms capacity and chamber size.
Packing, MOQ and Lead Time
Prices can be quoted for one hand-wheel autoclave or for a number of units. The quotation gives packing, delivery time and price for the quantity, and any laboratory autoclave sterilizer in India from the same range can be compared on it.
With an Importer-Exporter Code, Science Lab Supplies can ship to buyers in Uganda, the UAE, Saudi Arabia, Oman, the Philippines and Nepal. For this model, raise a request on the contact page, collect it with other items in the enquiry cart, or use the lab tender page for formal tenders.
Frequently Asked Questions
How many programs does it have?
It has five fixed and four DIY programs, set for different loads such as dressings, equipment, tools, rubber, liquid, culture medium and waste. The whole cycle then runs automatically.
What happens if the door is open or the water runs low?
A door sensor stops operation if the door is open. If the water level is too low, the anti-dry-out function powers the system off and shows an error code.
Is a printer included?
The printer is optional and records sterilisation data when fitted. Ask for it to be added to the quotation if your laboratory needs printed records of each cycle.
Who supplies the Hand Wheel Type Vertical Autoclave?
Science Lab Supplies, operating from Ambala, India, supplies this vertical autoclave, prepares its quotation and arranges dispatch. Petri dishes, incubators and other items can be added to the same consignment.
Related Autoclaves and Sterilizers
These include another hand-wheel vertical unit with pulse vacuum, a flip-open vertical design, table-top steam units in Class S, B and N, a dental size and a dry-heat sterilizer. Compare program range, chamber size and supply against the workload; any can join this quotation.
- Hand Wheel Vertical Pulse Vacuum Autoclave — pulse vacuum unit with a removable probe reading liquid temperature.
- Flip Open Door Type Vertical Autoclave — 30–100 L, maximum pressure 0.3 MPa, on 220 V.
- Table Top Autoclave Class S — open water tank with water quality monitor and internal filter.
- Table Top Autoclave Class B — five sizes from 18 to 80 L, design pressure −0.1/0.3 MPa.
- Table Top Autoclave Class N — 18 and 24 L, 121 and 134 °C, with hand lock door.
- Table Top Dental Sterilizer — 2 L and 8 L sizes in Class N or Class B.
- Hot Air Sterilizer — timing range 1–9999 min with two shelves.
Browse the full Autoclaves range, the Biology Lab range for incubators and culture work, or all laboratory equipment.
Last updated: 22 October 2026