Horizontal Autoclave
Product Code : LSK-A-11376
Horizontal Autoclave (SKU LSK-A-11376) is a horizontal steam sterilizer that removes cold air from the chamber by positive-pressure exhaust and runs programs for fabric, instruments, rubber and liquids. It comes in 100 L, 135 L, 185 L and 300 L sizes with a built-in steam generator, touch screen and printer. Science Lab Supplies arranges supply of this autoclave from Ambala, India, quoting medical institutions, laboratories, distributors and tender contractors.
Specifications
All four sizes of the horizontal autoclave are detailed in the table. In short, each uses a 304 medical stainless steel chamber rated to 0.23 MPa and 105–136 °C with ±0.1 °C accuracy, post-drying to below 3% residual humidity, four-level user authority and a 380 V, 50 Hz supply.
| Specification | Value |
|---|---|
| SKU | LSK-A-11376 |
| Type | Horizontal steam autoclave with positive-pressure air exhaust |
| Capacity options | 100 L, 135 L, 185 L, 300 L |
| Chamber size | Ø400 x 850 mm; Ø500 x 710 mm; Ø500 x 950 mm; Ø632 x 1000 mm (100/135/185/300 L) |
| Chamber material | 304 medical stainless steel |
| Max working pressure | 0.23 MPa |
| Working temperature | 105–136 °C |
| Temperature accuracy | ±0.1 °C |
| Sterilising programs | Fabric, instrument, rubber, liquid |
| Air removal | Positive-pressure air-exhaust system |
| Drying | Post-drying to residual humidity below 3% |
| Display | Touch screen: temperature, pressure, time, running status, failure warning |
| Steam source | Built-in steam generator |
| Control | Microcomputer temperature control |
| Printer | Prints date, time and process parameters |
| Access control | Four-level authority management |
| Safety devices | Over-heat auto protection, dual door safety lock, over-pressure relief valve, short-circuit/over-pressure protection |
| Power consumption | 11 kW or 17 kW, depending on size |
| Power supply | 380 V, 50 Hz |
| External size | 1250 x 730 x 1660; 1110 x 750 x 1742; 1350 x 750 x 1742; 1400 x 890 x 1780 mm |
| Packaging size | 1450 x 1000 x 1950; 1370 x 890 x 2060; 1510 x 890 x 2060; 1700 x 1050 x 2090 mm |
| Gross weight | 310 kg; 470 kg; 540 kg; 830 kg |
| Supplied by | Science Lab Supplies, Ambala, India |
Applications and Experiments for the Horizontal Autoclave
After loading, the operator chooses one of four programs on the touch screen. Positive pressure pushes cold air out of the chamber, steam sterilisation follows at the set temperature, and post-drying lowers residual humidity below 3%, while the printer logs date, time and process parameters for the record.
- Instrument loads, for example in an Instrument Tray Stainless Steel with cover, an item suited to steam sterilizers.
- Fabric and rubber loads, each on its own program.
- Liquid program for suitable containers, and autoclavable utensils such as the 475 ml Kidney Basin Polypropylene.
Pressurised steam and hot chamber surfaces can cause serious burns; installation should be by qualified technicians and operation by trained staff only.
Standard Scope of Supply
One Horizontal Autoclave is supplied in the capacity you select, complete with its built-in steam generator, touch-screen controller, printer and the safety devices listed above. Loading trays, consumables or installation support can be added to the same quotation if required.
Packing, MOQ and Lead Time
Ask for one horizontal autoclave or several units for different sites. The quotation shows packing, delivery time and price for each capacity and quantity requested, and hospital lab equipment such as trays, basins or incubators can be priced alongside it on one document.
With an Importer-Exporter Code, Science Lab Supplies is able to ship to buyers in Ghana, Ethiopia, Tanzania, Uganda, the UAE and Saudi Arabia. Name the capacity you need on the contact page or in the enquiry cart; buyers working to a tender can check the lab tender page.
Frequently Asked Questions
How does this autoclave remove air from the chamber?
It uses a positive-pressure air-exhaust system to drive cold air out of the chamber before sterilisation. By contrast, the Horizontal Pulse Vacuum Autoclave uses pulse vacuum with a −0.08 MPa limit.
How dry are loads after a cycle?
The post-drying function brings the residual humidity of sterilised articles below 3%. Drying depends on correct loading, so avoid overfilling the chamber or packing items tightly.
What electrical supply is needed?
The unit is rated for 380 V, 50 Hz, drawing 11 kW or 17 kW depending on size. Ask a qualified electrician to confirm the site supply before delivery.
Who supplies the Horizontal Autoclave?
Anyone buying a horizontal autoclave in India can have it quoted, packed and shipped by Science Lab Supplies from Ambala. Other laboratory equipment can go on the same quotation.
Related Autoclaves and Sterilizers
These units add pulse vacuum and larger horizontal designs, vertical and table-top formats, and a model with electric or gas heating. Comparing them helps balance capacity, door type and power supply against the workload, and any of them can join this quotation.
- Horizontal Pulse Vacuum Autoclave — pulse vacuum to −0.08 MPa with B&D, PCD and leakage test programs.
- Large Horizontal Autoclave — door with concave-convex tooth structure; chamber surface Ra≤0.5.
- Horizontal Cylindrical Pressure Autoclave — sterilisation and drying times each set from 0 to 60 min.
- Large Capacity Pulse Vacuum Autoclave — double-layer body with circular-arc chamber corners.
- Flip Open Door Type Vertical Autoclave — 30–100 L vertical unit with spring-assisted flip-open door.
- Table Top Autoclave Class B — 18–80 L unit with open water tank and water quality monitor.
- Portable Autoclave — two safety valves, with electric or gas heating.
Browse the full Autoclaves range, the Medical Utensils range for trays and basins, or all laboratory equipment.
Last updated: 22 October 2026