Daniell Cell, Copper with Zinc

Daniell Cell, Copper with Zinc

Product Code : LSK-CL-10047

The Daniell Cell, Copper with Zinc is a classic Daniell cell for electrochemistry. A heavy gauge copper vessel holds copper sulphate solution and a porous pot, and a zinc rod stands in the pot on a waxed wooden cap. The theoretical voltage of the cell is 1.1 volts.

Specifications of the Daniell Cell

SpecificationValue
Outer vesselHeavy gauge copper
Crystal shelfInternal perforated shelf for copper sulphate crystals
SeparatorPorous pot
Negative electrodeZinc rod fitted with a waxed wooden supporting cap
Theoretical voltage1.1 V
Supplied byScience Lab Supplies, Ambala, India

Running a Daniell Cell in the Electrochemistry Lab

The copper vessel is filled with copper sulphate solution and a few crystals are placed on the shelf. The porous pot holds the zinc-side electrolyte, usually zinc sulphate solution, and the zinc rod sits in it. Leads from the vessel and the rod go to a meter.

  • EMF of the cell (Class 12): connect the cell to a Digital Voltmeter and compare the steady reading with the theoretical 1.1 V.
  • Effect of concentration: repeat with weaker copper sulphate solution and record how the EMF changes, as the Nernst equation predicts.
  • Porous pot or salt bridge: set up the same pair of half-cells in two beakers joined by a Salt Bridge and compare the readings.
  • Current flow: connect a small lamp or a galvanometer and watch copper build up on the vessel side over a lesson.

Common errors: dirty or oxidised zinc, a dry porous pot, and taking a reading before the meter has settled.

Frequently Asked Questions

What is a gravity Daniell cell?
It is an older form with no porous pot. Dense copper sulphate solution lies at the bottom around the copper, and lighter zinc sulphate solution floats above it around the zinc. It must stand still and supply only small currents, so the porous pot design suits a school bench better.

Which solutions are needed before the cell can be used?
The copper vessel takes copper sulphate solution, with a few crystals on the shelf to keep it saturated. The porous pot takes zinc sulphate solution around the zinc rod. Copper sulphate can damage the eyes and harms aquatic life, so wear goggles and do not pour it down the drain.

Which ions pass through the porous pot while the cell works?
Sulphate ions move through the pot wall towards the zinc side, where zinc ions are being formed, and some zinc ions move the other way. This flow keeps both solutions electrically neutral, so current can keep flowing round the outer circuit.

Why does my reading come out below 1.1 volts?
The 1.1 V figure applies to standard conditions. Lower readings usually come from weak or impure solutions, a tarnished zinc rod, poor contacts, or drawing current while reading. Clean the zinc and read with a high-resistance voltmeter.

How does a Daniell cell differ from a simple copper and zinc cell in acid?
In a simple cell both metals stand in one acid, and hydrogen bubbles on the copper soon lower the voltage. In a Daniell cell each metal sits in a solution of its own salt, kept apart by the porous pot, so copper is deposited instead of hydrogen and the voltage stays steadier.

Related Electrochemical Cell Apparatus

Browse the Chemistry Lab range or the School Lab Equipments range.

Science Lab Supplies holds an Importer-Exporter Code and ships to buyers in Qatar, Sri Lanka, Vietnam, Malaysia, Peru and Egypt. To request a quotation, use the contact page or the enquiry cart.

Last updated: 15 November 2026

   
Supply of Daniell Cell, Copper with Zinc from to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, India (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe

Office Address

Works:Plot No. 448, HSIIDC. Industrial Area Saha, Haryana

[email protected]

+91-97290-66999

Follow Us