Burette Stand with Double Burette Clamp
Product Code : SCL-CL-12016
The Burette Stand with Double Burette Clamp holds two burettes side by side for titration. A spring-loaded, scissor-action double clamp on a 600 mm stainless steel rod grips each burette from the sides, so the graduations stay in view. The powder-coated cast iron base measures 200 × 125 mm.
Specifications of the Burette Stand
| Specification | Value |
|---|---|
| Base | Powder-coated cast iron, 200 × 125 mm |
| Rod | Grade 304 stainless steel, 600 mm long, 12 mm diameter |
| Clamp | Double burette clamp, spring-loaded scissor action, rubber-cushioned jaws |
| Burette fit | 10 ml, 25 ml and 50 ml burettes |
| Contents | Base, rod and one double clamp |
| Supplied by | Science Lab Supplies, Ambala, India |
Setting Up a Titration on the Burette Stand
Screw the rod into the base and tighten it. Slide the clamp hub onto the rod and lock it with the rear thumbscrew. Squeeze one side of the clamp, place the burette between the pads and release.
- Acid-base titration: run a Borosilicate Glass Burette 50ml into a Conical (Erlenmeyer) Flask, 250 ml standing on a white tile, swirling after each addition.
- Two burettes at once: hold an acid burette and a base burette together for a back titration, or to compare two titrants.
- Water testing: run two samples side by side and compare the endpoint colours.
Common errors: a loose delivery tip, filling the burette with the tap open, reading the scale at an angle and overshooting the endpoint.
Frequently Asked Questions
How do I change the height of one burette?
Squeeze that side of the clamp to open the pads, slide the burette to the new height and release. To move the whole clamp, loosen the rear thumbscrew. Never slide the glass while the jaws are closed on it.
Will the clamp hide the scale on the burette?
No. The scissor jaws grip the barrel from the sides, so the numbers and lines on the front stay readable all through the titration.
Why should the tap be closed while the burette is filled?
With the tap open, liquid runs straight through onto the bench and the base. Close it, fill with a small funnel to just above zero, remove the funnel, then run a little out to clear air from the tip.
What usually causes a wrong titre on this stand?
A reading taken with the eye above or below the meniscus, a tip that leaks or holds an air bubble, or titrant added too fast near the endpoint. Keep the burette upright and read at eye level.
Is a white tile needed with this stand?
For colour titrations, yes. The black base gives a poor background, so a white tile or a sheet of white paper under the flask makes a faint endpoint colour much easier to see.
Should a lab order the complete stand or only a double clamp?
The complete stand suits a new titration bench, since the base, 600 mm rod and double clamp come together. A lab that already has sturdy retort stands may need only a separate double clamp, chosen to fit the diameter of its existing rods.
Related Titration Apparatus
- Double Burette Clamp, Scissor Type (Pack of 2): scissor-action double clamp for rods up to 16 mm.
- Burette Storage Rack: wood and metal wall rack for up to 12 burettes.
- Burette, 50 ml, with Sampler Nozzles: graduated glass tube with a bottom stopcock.
- Burette for Acids, 25 ml: glass burette with stopcock and 0.1 ml divisions.
- Ring Stand Set, Rectangular Base, with Burette Clamp and Rings: includes a burette/flask clamp with boss head.
Find more titration stands in Chemistry Lab, and burettes in Glassware Burette.
Science Lab Supplies is registered as an importer-exporter and can arrange shipment to Tanzania, Uganda, the UAE, Saudi Arabia, Oman and the Philippines. Ask for a quotation through the contact page, or collect items in the enquiry cart first.