Burette for Acids, 25 ml
Product Code : SCL-CL-11471
This burette for acids is a 25 ml graduated glass tube with a glass stopcock at the base. Its 0.1 ml divisions let students run in an acid titrant drop by drop and read the volume used.
Specifications of the Burette for Acids, 25 ml
| Specification | Value |
|---|---|
| Capacity | 25 ml |
| Graduation | 0.1 ml divisions |
| Material | Glass, heat and chemical resistant |
| Tap | Glass stopcock (faucet) |
| Supplied by | Science Lab Supplies, Ambala, India |
Acid-Base Titrations with the 25 ml Burette
Rinse the burette with a little of the acid, fill it above zero, then run some out to fill the tip and clear bubbles. Clamp it upright, note the start reading and add acid to the flask while swirling.
- Standardising an alkali: titrate sodium hydroxide, measured with a Graduated Pipettes 25ml, against hydrochloric acid in a Conical Flask (Erlenmeyer) with Stopper.
- Sodium carbonate against acid: use methyl orange and repeat until two titres agree within 0.1 ml.
- Vinegar strength: run diluted vinegar from the burette into a measured volume of standard alkali with phenolphthalein.
Common errors: reading the top of the meniscus, leaving an air bubble in the tip, and not rinsing with the titrant first.
Frequently Asked Questions
Why is a glass stopcock burette used for acids?
Acids do not attack the ground-glass tap, so it keeps turning freely. Strong alkalis slowly etch and bind ground glass, which is why bases are usually run from a burette with a plastic tap.
How is a 0.1 ml burette read?
Read the bottom of the meniscus at eye level and record to two decimal places, ending in 0 or 5. A white card with a dark line held behind the tube makes the meniscus easier to see.
Why rinse the burette with the acid before filling?
Water left inside dilutes the acid and makes each titre too large. A small rinse with the acid itself removes it.
What are concordant results?
Titres that agree within 0.1 ml. Do a rough run first, then accurate runs until two or three agree, and average only those.
What should be done if the stopcock leaks?
Take the tap out, clean and dry the key and barrel, and apply a thin film of stopcock grease away from the bore. A leaking tap gives false high titres.
Related Titration Apparatus
- Burette for Acids, 50 ml: 50 ml glass burette with a glass faucet and 0.1 ml divisions.
- Burette for Bases, 25 ml: 25 ml glass burette with a tap and valve in place of a glass stopcock.
- Burette Clamps with Fasteners: mild steel clamps with rubber-covered, self-closing jaws.
- Retort Stand Set with Clamps and Rings: base and rod with counter clamp, middle clamp and two metal rings.
- Pipette Filler Bulb: creates suction for filling pipettes up to 25 ml.
Browse the Chemistry Lab range or the Glassware Burette range.
Science Lab Supplies is registered as an importer-exporter and can send orders to the Philippines, Nepal, Bangladesh, Zambia, Rwanda and South Africa. To request a quotation, send the item list through the contact page or the enquiry cart.
Last updated: 13 November 2026