Absorption in Packed Column
Product Code : LSK-TWL-10804
Absorption in Packed Column (SKU LSK-TWL-10804) is a mass transfer trainer that demonstrates the basics of gas absorption as a chemical engineering unit operation. Feed gas and absorption liquid meet in a glass packed column, so every stage of the process is visible. It is used in mass transfer labs of degree and diploma chemical engineering courses and for project work. Science Lab Supplies manufactures it at its factory at Plot 448, HSIIDC Industrial Area, Saha, Ambala, India, and sells it direct to colleges, tender contractors and distributors.
Specifications
Every technical detail of the trainer is listed in the table below. In short, it is a glass packed absorption column in which the absorption liquid and feed gases exchange mass, with complete visual monitoring, pressure drop studies across the bed and the option to run humidification and stripping experiments.
| Specification | Value |
|---|---|
| SKU | LSK-TWL-10804 |
| Column material | Glass |
| Column type | Packed absorption column |
| Working principle shown | Gas absorption via a wetted wall system |
| Contacting phases | Absorption liquid and feed gases |
| Pressure drop | Across the packed bed, for determining column diameter |
| Comparison | Absorption characteristics of packed columns |
| Additional studies | Humidification and stripping |
| Monitoring | Complete visual monitoring of the process |
| Operation | Easily operated; no further development work necessary |
| Use | Teaching, project and research work |
| Manufacturer | Science Lab Supplies, Saha, Ambala, Haryana |
| Country of origin | India |
Applications and Experiments for the Absorption in Packed Column
The column is used to show how a soluble gas passes into a liquid across a packed bed and to compare absorption characteristics of packed columns. Pressure drop readings across the bed introduce column sizing, since determining column diameter depends on that analysis, a standard topic in mass transfer practicals.
- B.Tech/B.E. chemical engineering mass transfer lab: gas absorption in a packed column, with uptake of an acidic gas followed in the liquid on a Bench pH Meter.
- Pressure drop across the packed bed, read for example on a U-Tube Manometer, and its role in finding column diameter.
- Humidification and stripping as related gas-liquid operations.
- Diploma chemical engineering and final-year project or research work.
Standard Scope of Supply
The unit is supplied as a single set-up built around the glass packed absorption column for gas-liquid contact, as described above; any optional accessories are listed on the quotation. The feed gas, absorption liquid and any analysis glassware are provided by the laboratory according to the system it studies.
Packing, MOQ and Lead Time
Quotations are available for one column or for a complete mass transfer lab, and every quotation from Science Lab Supplies states the packing, delivery time and price for the requested quantity. Departments buying engineering lab equipment in India can add related separation trainers to the same quotation.
As a registered exporter with an Importer-Exporter Code, Science Lab Supplies can ship to buyers in Ghana, Ethiopia, Tanzania, Uganda, the UAE and Saudi Arabia. The business is registered under Udyam as a manufacturing enterprise (UDYAM-HR-01-0014546) and for GST (GSTIN 06ADEPJ0574F2ZU). Send enquiries through the contact page or the enquiry cart, and use the lab tender page for tender supply.
Frequently Asked Questions
What can students study on the Absorption in Packed Column?
They can study gas absorption into a liquid, compare the absorption characteristics of packed columns, measure pressure drop across the bed, and run humidification and stripping experiments on the same unit.
Why is the column made of glass?
The glass column gives complete visual monitoring, so students can watch liquid distribution, wetting of the packing and gas-liquid contact while they record their readings.
Is Science Lab Supplies the manufacturer or a trader?
Science Lab Supplies is the manufacturer. The column is built at its own factory in Saha, Ambala, India, and quotations come directly from the factory.
Can it be used for project work?
Yes. The unit is described as suitable for project or research work as well as routine teaching practicals, which makes it useful for final-year student projects.
Related Mass Transfer and Separation Equipment
These units fit a mass transfer and separation lab alongside the packed absorption column. They add a wetted wall absorption design, packed-bed flow and fluidisation studies, extraction, evaporation, membrane separation and bench distillation glassware, covering the unit operations chemical engineering courses teach together.
- Gas Absorption Column — gimbal-mounted glass wetted wall column with deoxygenating column, oxygen analyser and CO2 absorption into caustic soda.
- RTD Studies in Packed Bed — glass column packed with Raschig rings, with rotameter and tracer injection.
- Fluidisation and Fluid Bed Heat Transfer Unit — glass bed chamber with manometer for pressure drop through packed and fluidised beds.
- Solid Liquid Extraction Unit — semi-batch extraction with spherical vessel, heating bath, condenser and reflux divider.
- Rising Film Evaporator — vertical long tube evaporator; such units serve as reboilers for distillation columns.
- Reverse Osmosis Ultra filtration Unit — membrane module taking RO and UF membranes, with pressures variable up to 55 bar.
- Fractional Distillation Assembly — borosilicate glass set with Vigreux column, Liebig condenser and 250 ml boiling flask, 19/26 joints.
Browse the full Training Workshop Labs range, the Chemistry Lab range for distillation glassware, or all TVET lab equipment.
Last updated: 9 October 2026