Liquid Chromatography Digital System
Product Code : LSK-TWL-10806
Liquid Chromatography Digital System (SKU LSK-TWL-10806) is a high-performance liquid chromatography (HPLC) instrument for separating and quantifying compounds in solution. It combines gradient pumping, vacuum degassing, a temperature-controlled column compartment and a choice of UV/Vis, photodiode array or refractive index detection. Analytical chemistry, pharmacy and process engineering labs use it. Science Lab Supplies supplies it from Ambala, India to universities, research laboratories, training institutes, tender contractors and distributors.
Specifications
Every technical detail is listed in the table below. In short, it pairs a quaternary low-pressure or binary high-pressure gradient pump with a four-channel vacuum degasser, a column compartment controlled from 4 to 90 °C, and a choice of UV/Vis, 1024-channel PDA or RI detection.
| Specification | Value |
|---|---|
| SKU | LSK-TWL-10806 |
| Quaternary pump principle | Parallel dual-plunger, low-pressure gradient |
| Quaternary gradient formation | 4-channel mixing valve |
| Number of solvents | Up to 4 |
| Composition precision | < 0.1% |
| Composition accuracy | < 0.5% |
| Binary pump principle | Double parallel dual-plunger, high-pressure gradient |
| Degasser channels | 4 |
| Degasser maximum flow | 10 ml/min per channel |
| Degassing performance | 0–2.0 ml/min per channel for 70% gas removed from methanol |
| Degasser internal volume | 925 µl per channel |
| Degasser wetted materials | Teflon AF, PEEK, glass-filled PTFE |
| Column temperature range | 4 °C (cooling) to 90 °C |
| Column temperature stability | ±0.05 °C |
| Column temperature accuracy | ±0.5 °C |
| Column capacity | Up to 3 x 30 cm analytical or 2 x 30 cm semi-prep |
| UV/Vis wavelength range | 190–900 nm, dual wavelength |
| UV/Vis drift | < 1 x 10⁻⁴ AU/h |
| UV/Vis noise | < ±0.5 x 10⁻⁵ AU (254 nm, dry cell) |
| UV/Vis linearity | > 99.5% for 2.5 AU (acetone, 254 nm) |
| UV/Vis data rate | Up to 50 Hz |
| PDA channels | 1024 |
| PDA wavelength range | 190–950 nm |
| PDA noise | 2 x 10⁻⁵ AU (empty cell, 1 s rise time, 254 nm) |
| PDA drift | 2 x 10⁻⁴ AU/h (baseline correction); 0.001 AU/h (room temperature) |
| PDA wavelength accuracy | 1 nm (holmium oxide filter) |
| RI range | 1.00–1.75 RIU |
| RI flow cell volume | 9 µl (analytical) / 7 µl (semi-prep) |
| RI noise | ≤ 5 x 10⁻⁹ RIU (analytical) / ≤ 10 x 10⁻⁸ RIU (semi-prep) |
| Supplied by | Science Lab Supplies, Ambala, India |
Applications and Experiments for the Liquid Chromatography System
The system is used to separate, identify and quantify components of liquid samples, from drug assays and impurity profiles to sugars, organic acids and reaction products. It supports instrumental analysis practicals in chemistry and pharmacy degrees and analytical work in engineering and biotechnology research laboratories.
- M.Sc./B.Sc. chemistry: instrumental analysis with isocratic and gradient elution, with solvents filtered on the Equipment for Vacuum Filtration.
- B.Pharm/M.Pharm pharmaceutical analysis: assay and related-substance methods, with buffer pH set on a Bench Digital pH Meter.
- Biotechnology and chemical engineering: sugars and reaction products by RI or UV detection.
Standard Scope of Supply
The specification covers the quaternary or binary pump, the four-channel vacuum degasser, the column compartment and the UV/Vis, PDA and RI detector options; your chosen configuration is itemised on the quotation. Columns, solvents, standards and a computer are not listed and are quoted separately if required.
Packing, MOQ and Lead Time
Ask for a quotation for one system in the pump and detector configuration you need, or for several for a teaching lab. Each Science Lab Supplies quotation states the packing, delivery time and price, which helps when comparing test and measurement instruments in India.
As a registered exporter with an Importer-Exporter Code, Science Lab Supplies can ship to buyers in Tanzania, Uganda, the UAE, Saudi Arabia, Oman and the Philippines. Contact us through the contact page or the enquiry cart, and see the lab tender page for tenders.
Frequently Asked Questions
Which detectors are available for the Liquid Chromatography Digital System?
The specification lists a dual-wavelength UV/Vis detector (190–900 nm), a 1024-channel photodiode array detector (190–950 nm) and a refractive index detector for compounds without UV absorbance, such as sugars.
Does the system need special handling?
HPLC work uses organic solvents such as methanol, which are flammable and toxic. Handle them under supervision in a ventilated area and dispose of solvent waste under your institution's rules.
Who supplies the Liquid Chromatography Digital System?
Science Lab Supplies supplies it from Ambala, India, and quotes it with the pump and detector configuration you select for your laboratory or research group.
Are columns and solvents included?
They are not listed in the specification. Tell us the columns, solvents or standards you need through the contact page and they can be added to the same quotation.
Related Separation, Process and Chromatography Equipment
These units produce or teach the separations a chromatography system analyses. Extracts, enzyme reaction mixtures and membrane permeates can be quantified by HPLC, while the classroom kits introduce column and paper chromatography before students use the instrument on real samples.
- Solid Liquid Extraction Unit — semi-batch solvent extraction of solids held in a glass fibre bag.
- Rapid Extractor — high-pressure extraction of active constituents in laboratory-scale batches.
- Batch Enzyme Reactor — glucose isomerase reaction producing glucose and fructose mixtures.
- Reverse Osmosis Ultra filtration Unit — membrane module supplied with both RO and UF membranes.
- Ion Exchange Chromatography Kit — ion-exchange columns, buffer and chemical mixture for 6 separations by net charge.
- Chromatography Set — beaker, filter paper and coloured pens for teaching pigment separation.
Browse the full Training Workshop Labs range, the Chemistry Lab range for glassware and meters, or all TVET lab equipment.
Last updated: 9 October 2026