Swiftlock Autoclave
Product Code : LSK-A-11394
Swiftlock Autoclave (SKU LSK-A-11394) is an automatic steam autoclave with a stainless steel vessel that, once filled with water, runs its whole cycle on its own at a selectable 100–138 °C. Safety centres on a pressure-activated door lock, two thermal cooling locks, an 80 °C cool interlock for fluids and alarms for sterilization failure, low water and an unlocked door. It suits research, university and college laboratories. Science Lab Supplies can deliver it from Ambala, India, to laboratories, contractors and resellers.
Specifications
This automatic steam autoclave's safety and control features are listed one per row below. In short, it combines a stainless steel vessel and base shelf, a 100–138 °C range at 0.2–2.4 bar, a colour touchscreen, low water and power use, and layered protection from cut-outs, cooling locks and audio-visual alarms.
| Specification | Value |
|---|---|
| SKU | LSK-A-11394 |
| Vessel | Stainless steel |
| Shelf | Base tray / shelf |
| Variable temperature range | 100–138 °C |
| Corresponding pressure | 0.2–2.4 bar |
| Automation | Fully automatic once filled with water |
| Eco design | Low water and low power use; minimum water needed per cycle |
| User interface | Icon-driven colour touchscreen |
| Thermocouple validation gland | Fitted, with easy-access panel |
| Gauge test port | Fitted |
| Safety valve test cycle | Included |
| Over-temperature and over-pressure | Automatic cut-out |
| Cool interlock | 80 °C, on fluid cycles only |
| Door lock | Pressure-activated |
| Thermal cooling locks | Two |
| Overheat protection | Fitted |
| Alarms | Sterilization failure, water low, door unlocked |
| Audio-visual signals | End of cycle, cycle fault, cycle interruption |
| Supplied by | Science Lab Supplies, Ambala, India |
Applications and Experiments for the Automatic Steam Autoclave
The autoclave can sterilize media, glassware and laboratory waste with steam at any setting from 100 to 138 °C. Because it locks itself under pressure and signals every fault, it suits shared teaching labs where several users run cycles, from undergraduate microbiology to postgraduate research groups.
- Undergraduate microbiology: preparing glass plates such as the Petri Dish (Set) and liquid media on fluid cycles.
- Research laboratories: treating used cultures in Autoclave Bags before disposal.
- Laboratory safety training: explaining the cool interlock, door lock and alarm signals to new users.
Standard Scope of Supply
Each order covers the autoclave with its stainless steel vessel, base tray or shelf, colour touchscreen, thermocouple validation gland and easy-access panel, gauge test port, and the complete lock, cut-out and alarm system described above. The chamber size and electrical supply are stated on the quotation.
Packing, MOQ and Lead Time
Whether you need one autoclave or one for every teaching lab in a block, the quotation gives the packing, delivery time and price for that number. Autoclave bags, glassware and other laboratory instruments in India can be added, so the department receives one consolidated price.
Science Lab Supplies operates with an Importer-Exporter Code and can ship to buyers in Egypt, Iraq, Nigeria, Kenya, Ghana and Ethiopia. Put your requirement to us on the contact page, build a list in the enquiry cart, or use the lab tender page for sealed bids.
Frequently Asked Questions
What alarms and signals does it give?
It alarms for sterilization failure, low water and an unlocked door, and gives audio-visual signals for end of cycle, cycle fault and cycle interruption, so users know the state of every run.
How is the door kept shut during a cycle?
A pressure-activated door lock keeps it closed while the chamber is pressurised, two thermal cooling locks add protection, and on fluid cycles the cool interlock holds until the load has fallen to 80 °C.
What temperature and pressure range does it cover?
The temperature can be varied from 100 to 138 °C, which corresponds to 0.2–2.4 bar. Over-temperature and over-pressure cut-outs and overheat protection guard the upper limit.
Who supplies the Swiftlock Autoclave?
For this laboratory autoclave in India, buyers deal with Science Lab Supplies, based in Ambala, which confirms the chamber size and electrical supply on each quotation and handles packing and dispatch for laboratories and distributors.
Related Automatic Autoclaves
These autoclaves extend the same automatic steam approach into low-water, top-loading and front-loading versions, plus table-top and vertical units with their own control features, so a laboratory can compare the options and quote any of them alongside this one on a single request.
- Automatic Autoclave Swiftlock Ecofill — thermocouple validation gland and gauge test port.
- Automatic Autoclave Swiftlock Man Fill 95L Top Load 230V — 95 L top-loading, manual-fill model for 230 V.
- Automatic Autoclave Swiftlock Front Load — manual filling with a base shelf.
- Table Top Autoclave Class N — automatic malfunction detection system.
- Table Top Autoclave Class S — 144 °C design temperature and -0.1/0.3 MPa design pressure.
- Hand Wheel Vertical Pulse Vacuum Autoclave — built-in printer and LCD error codes.
Browse the full Autoclaves range, the Clinical Laboratory range, or all laboratory equipment.