Hofmann Voltameter Stand
Product Code : LSK-CL-10245
The Hofmann Voltameter Stand holds a Hoffman's voltameter upright during electrolysis of water. It is a metal stand with a support clamp and comes with a 600 mm rod, so the glass unit stays steady while it is filled, run and read.
Specifications of the Hofmann Voltameter Stand
| Specification | Value |
|---|---|
| Type | Metal stand with support clamp |
| Rod | 600 mm, supplied |
| For use with | Hoffman's voltameter |
| Supplied by | Science Lab Supplies, Ambala, India |
Setting Up the Voltameter on Its Stand
Fit the rod to the base and tighten it. Set the clamp at a height where the reservoir bulb is easy to fill and the graduations are at eye level. Close the clamp gently on the glass, never tightly.
- Mount a Hoffman Voltameter With Electrodes and check that both limbs are vertical before reading gas volumes.
- Place the stand near the AC/DC Laboratory Power Supply so the leads reach the terminals without pulling on the glass.
- Fill through the funnel bulb with the clamp in place, so the stand takes the weight of the electrolyte.
Common errors: over-tightening the clamp, which can crack the glass; leaving the rod loose in the base; and setting the stand at the edge of the bench.
Frequently Asked Questions
Which voltameters does the stand hold?
It is made for the Hoffman's voltameter, the three-tube glass apparatus with two graduated limbs and a central reservoir. The support clamp grips the glass unit and holds it clear of the bench.
Is the rod included?
Yes. The stand comes with a 600 mm rod. This length lets the voltameter be set high enough for filling through the reservoir bulb and for reading the graduations comfortably.
Why must the voltameter be held exactly upright?
Gas volumes are read against the graduations on each limb. If the limbs lean, the liquid surface sits at an angle and the readings are wrong. A vertical tube also lets gas rise freely to the stopcock.
Can a normal retort stand be used instead?
A retort stand with a suitable clamp can hold the voltameter. This stand keeps the glass at a working height and leaves the bench clear for the power supply and splints.
How high should the voltameter be clamped?
High enough that the electrode leads hang free of the bench and the graduations on both limbs sit close to eye level. Keep the whole unit in view while the gas collects.
How is the stand kept from tipping over?
Set the base on a flat, level bench and turn the clamp so the weight of the glass unit sits over the base, not out past its edge. Do not lean on the rod while the glass is clamped.
Related Electrolysis Equipment
- Hofmann Voltameter: 50 ml limbs graduated 50 x 0.2 ml, with removable carbon electrodes.
- Hofmann Voltameter, 25 ml Tubes, 600 mm: three glass tubes, two of them graduated, with ground glass taps.
- Platinum Foil Electrodes (Pair): rectangular platinum foil electrodes fused into glass tubes.
- Laboratory Retort Stand: weighted base with a vertical rod for supporting apparatus.
- Three Prong Glassware Holding Clamp: adjustable clamp for holding cylindrical glass vessels on a retort stand.
Browse the Chemistry Lab range or the wider school lab equipment section.
Holding an Importer-Exporter Code, Science Lab Supplies can ship to buyers in Qatar, Sri Lanka, Vietnam, Malaysia, Peru and Egypt. To ask for a quotation, use the contact page or the enquiry cart.
Last updated: 15 November 2026