Bilirubin Meter
Product Code : LSK-CL-11282
Bilirubin Meter (SKU LSK-CL-11282) is a fully automatic bench-top analyser that measures bilirubin in a 10 µl whole-blood sample in about 3 seconds, with an accuracy of approximately 5%. A digital alphanumeric display and integrated printer present each result, and built-in software stores data or sends it to a PC. It suits clinical biochemistry modules in medical laboratory technology training. Science Lab Supplies can quote the meter from Ambala, India, for institutes, laboratories, tender contractors and distributors.
Specifications
Every specification of the bilirubin analyser is shown below. In summary, it is an open, fully automatic bench-top system taking 10 µl of whole blood and giving a result in 3 seconds with about 5% accuracy, with auto-calibration, self-diagnosis, quality-control flags, an integrated printer and PC data output.
| Specification | Value |
|---|---|
| SKU | LSK-CL-11282 |
| Platform | Bench-top, open, fully automatic system |
| Sample type | Whole blood |
| Sample volume | 10 µl |
| Analysis time | 3 seconds |
| Accuracy of measurement | Approximately 5% |
| Display | Digital alphanumeric display |
| Printer | Integrated |
| Calibration | Automated calibration and auto-calibration, with self-diagnosis |
| Quality control | Flags abnormal results |
| Data management | Built-in software; data can be printed or sent to a PC |
| Energy saving | Stand-by mode after 30 minutes |
| Operating humidity | Up to 80% |
| Operating temperature | 15°C to 35°C |
| Power requirements | 220 V/50 Hz, with voltage surge protection |
| User manual | CD with user manual (English) |
| Dust cover | 1 |
| Capillary tubes | 100 haematocrit micro capillary tubes |
| Sealing plasticine | 1 plate of capillary sealing plasticine |
| Printer paper | 1 thermal paper roll |
| Fuse kit | 1 |
| Power cable | AC power cable |
| Supplied by | Science Lab Supplies, Ambala, India |
Applications and Experiments for the Bilirubin Meter
The meter gives a quick bilirubin reading from a very small whole-blood sample collected in a capillary tube, so no serum separation step is needed. It can be used in DMLT, B.Sc. MLT and clinical biochemistry training to show how automatic analysers calibrate, flag abnormal results and report data.
- Clinical biochemistry practicals: measuring bilirubin on a 10 µl whole-blood sample in a haematocrit micro capillary tube.
- Capillary sampling technique with a Safety Lancet Disposable 2.4 mm under supervision, wearing Gloves Exam Latex Without Powder.
- Quality-control training: reviewing flagged abnormal results and the self-diagnosis routine.
- Data handling: printing results on the integrated printer or transferring them to a PC.
Handle all blood samples as potentially infectious and dispose of capillaries and lancets in a sharps container.
Standard Scope of Supply
The meter comes with a standard set of accessories, consumables and parts needed to operate it: a CD with the English user manual, a dust cover, 100 haematocrit micro capillary tubes, one plate of capillary sealing plasticine, one thermal paper roll, a fuse kit and an AC power cable.
Packing, MOQ and Lead Time
Request a quotation for one meter or for several to equip a clinical biochemistry teaching lab. Science Lab Supplies shows packing, delivery time and price for the quantity requested on each quotation, and extra capillary tubes, thermal paper or lancets can be priced on the same document.
Under its Importer-Exporter Code, Science Lab Supplies can ship to buyers in Malaysia, Peru, Egypt, Iraq, Nigeria and Kenya. Enquiries go through the contact page or the enquiry cart, and the lab tender page sets out the route for formal tenders.
Frequently Asked Questions
What sample does the bilirubin meter need?
It works on whole blood, with a sample volume of 10 µl. One hundred haematocrit micro capillary tubes and a plate of capillary sealing plasticine come in the accessory set, so the first samples can be run once the meter is installed.
How long does a measurement take?
Analysis time is about 3 seconds, and the accuracy of measurement is approximately 5%. The result appears on the digital alphanumeric display and can be printed straight away on the integrated printer.
What conditions can the meter operate in?
It tolerates humidity up to 80% and operating temperatures from 15°C to 35°C, runs on 220 V/50 Hz with surge protection, and switches to an energy-saving stand-by mode after 30 minutes.
Who supplies the Bilirubin Meter?
Ambala-based Science Lab Supplies prepares quotations for the meter for institutes, laboratories, tender contractors and distributors, adding spare capillary tubes, thermal paper rolls or related blood-sampling items when you ask.
Related Capillary Sampling and Analyser Equipment
Capillary blood work brings together collection items, sealing, centrifugation, safe disposal and other analysers, so the products below fit naturally beside the bilirubin meter, and any of them can be listed with it on one quotation for a clinical biochemistry or MLT training laboratory.
- Haematocrit Centrifuge — fixed approx. 13000 rpm for haematocrit capillary tubes, with a lid interlock.
- Capillary Tube Sealant — sealant with a 24-slot tray for holding capillary tubes.
- Micro Haematocrit Capillaries — sodium-heparinised capillaries, 75 mm x 1 mm, pack of 100.
- Clinical Chemistry Analyzer — batch determination of routine chemistry parameters in serum, plasma or urine.
- 18 parameter Haematology Analyser — stores at least 100 patient data and connects to a PC by USB.
- Microcuvette for Glucose — single-use cuvettes collecting 5–10 µl of capillary blood, box of 100.
- Sharp Container Leak Proof Plastic — puncture-resistant 4–6 L container with a tight-fitting lid.
Browse the full Clinical Laboratory range, the Diagnostic Equipment range, or all school lab equipment.
Last updated: 22 October 2026